Skip to main content

Table 1 Reliability Indices Determined by the Mean of Three Trials from Two Imaging Sessions

From: Measurement of tibial nerve excursion during ankle joint dorsiflexion in a weight-bearing position with ultrasound imaging

Measurement Position

Session 1 Mean nerve excursion(mm) (± SD)

Session 2 Mean nerve excursion(mm) (± SD)

đ(mm)(± SD)

ICC

ICC 95% CI

SEM (mm)

SRD (SRD%)

      

Session 1

Session 2

Session 1

Session 2

Weight-bearing

3.03 (1.07)

2.99 (0.86)

0.04 (0.47)

0.93

0.70-0.96

0.28

0.22

0.84 (27)

0.66 (22)

  1. đ = difference (mm) between session 1 & session 2